Product Details:
Place of Origin: Guangdong, China
Brand Name: Prostar or OEM/ODM
Certification: CE, EMC, IEC, LVD, RoHS, ISO9001, ISO14001
Model Number: PowerSolar PIS5K-48
Size: 140 x 295 x 540 mm
Weight: 15 Kgs
Input Voltage: 230Vac
Output Voltage: 200/208/220/230/240Vac
Output Frequency: 50Hz/60Hz
Output Power: 1 - 200KW
Output Type: Single
Type: DC/AC Inverters
Payment & Shipping Terms:
Minimum Order Quantity: 20 Piece/Pieces
Price: US $ 600 / Piece (basic on MOQ)
Packaging Details: Standard Export Carton Package.
Delivery Time: 15~20 days for Routine machine, once received deposit
Payment Terms: T/T or L/C. 30% deposit before production, 70% balance before shipment.
Supply Ability: 88000 Piece/Pieces per Month
Description

Prostar PowerSolar 48V 5KVA 4000 watt off grid inverter generator for solar power system

Prostar PowerSolar off-grid inverter is a multi-function inverter/charger, combining functions of inverter, solar charger and battery charger to offer uninterruptible power support with portable size. Its comprehensive LCD display offers user-configurable and easy-accessible button operation such as battery charging current, AC/solar charger priority, and acceptable input voltage based on different applications.

Overview

Prostar PowerSolar series inverters are equipped with MPPT solar charge controller to maximize and regulate DC power from the solar array for the charging the battery bank. Transformerless design provides reliable power conversion in compact size. Besides, it’s worry-free to start up motor-type loads such as refrigerators, motors, pumps, compressors and laser printers as well as electronic loads like TV’s, Computers, power tool and battery chargers.

 

4000 watt off grid inverter generator

Features

  1. Pure sine wave inverter

  2. Built-in MPPT solar charge controller

  3. Selectable input voltage range for home appliances and personal computers

  4. Selectable charging current based on applications

  5. Configurable AC/Solar input priority via LCD setting

  6. Compatible to mains voltage or generator power

  7. Auto restart while AC is recovering

  8. Overload and short circuit protection

  9. Smart battery charger design for optimized battery performance

  10. Cold start function

  11. Parallel operation with up to 6 units only available for 4KVA/5KVA

  12. Optional Remote Control Panel available

Technical Specification

 

Model PIS1K-24 PIS1K-48 PIS2K-24 PIS3K-24 PIS3K-48

PIS4K-48

PIS5K-48

RATED POWER 1KVA/0.8KW 1KVA/1KW 2KVA/1.6KW 3KVA/2.4KW 3KVA/2.4KW 4KVA/3.2KW 5KVA/4KW
INPUT
Voltage 120 VAC or 230 VAC 230 VAC
Selectable Voltage Range 95-140 VAC or 170-280 VAC (For Personal Computers)
65-140 VAC or 90-280 VAC (For Home Appliances)
170-280 VAC (For Personal Computers)
90-280 VAC (For Home Appliances)
Frequency Range 50 Hz/60 Hz (Auto sensing)
OUTPUT
AC Voltage Regulation (Batt. Mode) 110/120 VAC ± 5% (User
selectable) or 230VAC ± 5%
230VAC ± 5%
Surge Power 2000VA 4000VA 6000VA 8000VA 10000VA
Efficiency (Peak) 90%-93% 93%
Transfer Time 10 ms (For Personal Computers); 20 ms (For Home Appliances)
Waveform Pure sine wave
BATTERY & AC CHARGER
Battery Voltage 24 VDC 48 VDC 24 VDC 24 VDC 48 VDC 48 VDC
Floating Charge Voltage 27 VDC 54 VDC 27 VDC 27 VDC 54 VDC 54 VDC
Overcharge Protection 31 VDC 62 VDC 31 VDC 31 VDC 62 VDC 60 VDC
SOLAR CHARGER & AC CHARGER
Maximum PV Array Power 600 W 900 W 600 W 600 W 900 W 3000 W
MPPT Range @ Operating Voltage 30VDC~ 66VDC 60VDC~ 88VDC 30VDC ~ 66VDC 30VDC ~ 66VDC 60VDC ~ 88VDC 60VDC ~
115VDC
Maximum PV Array Open Circuit Voltage 75VDC 102VDC 75VDC 75VDC 102VDC 145VDC
Maximum Solar Charge Current 25A 18 A 25A 25A 18A 60A
Maximum AC Charge Current 10 A / 20 A 10 A / 15 A 20 A or 30 A 20 A or 30 A 10 A / 15 A 60 A
Maximum Charge Current 25A 18 A 30A 30A 18A 120A
Maximum Efficiency 98%
Standby Power Consumption 2 W
PHYSICAL
Dimension, D x W x H (mm) 100 x 272 x 355 140 x 295 x 540
Net Weight (kgs) 6.8 7.0 7.4 12.5 13.5
OPERATING ENVIRONMENT
Humidity 5% to 95% Relative Humidity(Non-condensing)
Operating Temperature 0°C - 55°C
Storage Temperature -15°C - 60°C
* There are charging current selection only available for 230VAC system.
Product specifications are subject to change without further notice

Download

Prostar PowerSolar Off grid Solar Inverter Catalog

Prostar PowerSolar Off grid Solar Inverter 4KVA/5KVA Manual

 

Basic System Architecture

The following illustration shows basic application for this inverter/charger. It also includes following devices to have a complete running system:

Consult with your system integrator for other possible system architectures depending on your requirements.

This inverter can power all kinds of appliances in home or office environment, including motor-type appliances such as tube light, fan, refrigerator and air conditioner.

solar electricity systems

Note: Appliances like air conditioner need at least 2~3 minutes to restart because it’s required to have enough time to balance refrigerant gas inside of circuits. If a power shortage occurs and recovers in a short time, it will cause damage to your connected appliances. To prevent this kind of damage, please check manufacturer of air conditioner if it’s equipped with time-delay function before installation. Otherwise, this inverter/charger will trig overload fault and cut off output to protect your appliance but sometimes it still causes internal damage to the air conditioner.

Product Details

solar inverter

solar invertersolar inverter

Inverter Installation

Unpacking and Inspection

Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. You should have received the following items inside of package:

  • The unit x 1

  • User’s manual x 1

  • Communication cable x 1

Preparation

Before connecting all wirings, please take off bottom cover by removing two screws as shown below.

Prostar PowerSolar Solar Inverter Installation       

Mounting the Unit

Consider the following points before selecting where to install:

  1.  Do not mount the inverter on flammable construction materials.

  2.  Mount on a solid surface

  3.  Install this inverter at eye level in order to allow the LCD display to be read at all times.

  4.  For proper air circulation to dissipate heat, allow a clearance of approx. 10 cm to the side and approx. 50 cm above and below the unit.

  5.  The ambient temperature should be between 0°C and 55°C to ensure optimal operation.

  6.  The recommended installation position is to be adhered to the wall vertically.

  7.  Be sure keep other objects and surfaces as shown in the below diagram to guarantee sufficient heat dissipation and to have enough space for removing wires.

Prostar PowerSolar Solar Inverter Mounting               Prostar PowerSolar Solar Inverter Installation

Battery Connection

CAUTION: To safety operation and regulation compliance, it’s requested to install a separate DC over-current protector or disconnect device between battery and inverter. It may not be requested to have a disconnect device in some applications, however, it’s still requested to have over-current protection installed. Please refer to typical amperage in below table as required fuse or beaker size.

WARNING! All wiring must be performed by a qualified personnel.

WARNING! It's very important for system safety and efficient operation to use appropriate cable for battery connection. To reduce risk of injury, please use the proper recommended cable and terminal size as below.

Recommended battery cable and terminal size:

Prostar PowerSolar Inverter battery connection cable size

Please follow below steps to implement battery connection:

1. Assemble battery ring terminal based on recommended battery cable and terminal size.

2. Units support 24VDC or 48VDC system. Connect all battery packs as units requires. It’s suggested to connect at least 100Ah capacity battery for each.

NOTE: Please only use sealed lead acid battery or sealed GEL/AGM lead-acid battery.

3. Insert the ring terminal of battery cable flatly into battery connector on the inverter and make sure the bolts are tightened to a torque of 2-3 Nm. Make sure polarity at both the battery and the inverter/charge is correctly connected and ring terminals are tightly screwed to the battery terminals.

PowerSolar Solar Inverter Battery Connection

AC Input/Output Connection

CAUTION!!  Before connecting to AC input power source, please install a separate AC breaker between inverter and AC input power source. This will ensure the inverter can be securely disconnected during maintenance and fully protected from over current of AC input. The recommended spec of AC breaker is 10A for 1KVA, 20A for 2KVA, 32A for 3KVA.

CAUTION!!  There are two terminal blocks with “IN” and “OUT” markings. Please DO NOT mis-connect input and output connectors.

WARNING!  All wiring must be performed by a qualified personnel.

WARNING!  It's very important for system safety and efficient operation to use appropriate cable for AC input connection. To reduce risk of injury, please use the proper recommended cable size as below.

PowerSolar Solar Inverter AC Cable Size

Please follow below steps to implement AC input/output connection:

1. Before making AC input/output connection, be sure to open DC protector or disconnector first.

2. Remove insulation sleeve 10mm for six conductors 1K/2K/3KVA. And shorten phase L and neutral N conductor 3 mm.

3. Insert AC input wires according to polarities indicated on terminal block and tighten the terminal screws. Be sure to connect PE protective conductor (ground line) first.

PowerSolar Inverter AC Input Connection

4. Then, insert AC output wires according to polarities indicated on terminal block and tighten terminal screws. Be sure to connect PE protective conductor (Ground Line) first.

PowerSolar Inverter AC Output Connection

5. Make sure the wires are securely connected.

PV Connection

CAUTION: Before connecting to PV modules, please install separately a DC circuit breaker between inverter and PV modules.

WARNING! All wiring must be performed by a qualified personnel.

WARNING! It's very important for system safety and efficient operation to use appropriate cable for PV module connection. To reduce risk of injury, please use the proper recommended cable size as below.

PowerSolar Inverter PV Connection Cable Size

Please follow below steps to implement PV module connection:

1. Remove insulation sleeve 10 mm for positive and negative conductors.

2. Check correct polarity of connection cable from PV modules and PV input connectors. Then, connect positive pole (+) of connection cable to positive pole (+) of PV input connector. Connect negative pole (-) of connection cable to negative pole (-) of PV input connector.

3. Make sure the wires are securely connected.

PowerSolar Inverter PV Connection

 

Final Assembly

After connecting all wirings, please put bottom cover by screwing two screws as shown below.

PowerSolar Inverter final Installation

OPERATION

PowerSolar Inverter power off on

Once the unit has been properly installed and the batteries are connected well, simply press On/Off switch (located on the button of the case) to turn on the unit.

 

Warranty

One year warranty after the date of delivery.

Payment Terms

Terms of payment is T/T or L/C. 30% deposit before production, 70% balance before shipment.

Contact Information

Contact Person: Mr. Orson

Email: inquiry@prostarsolar.net; orsonz.prostar@gmail.com

Skype: orsonz.prostar

Mobile: (+86)-13827733783 (whatsApp)

Website: www.prostarsolar.net

 

   Scan Wechat to talk with Orson directly!   

Scan Wechat to talk with Orson

 

Contact Us
Mr. Orson Zhong
  • 86-757-81285481-811
  • No.1 ShijieLang Road, Lianhe Industrial Zone West Two Zone, Luocun, Nanhai, Foshan, Guangdong, China
From:
Enter your Email ID please.
Send your inquiry directly to us
(93/3000)